Headless Automation Protocol v1

Domain: runtime host tooling. Function: normative.

This chapter defines the v1 automation wire contract owned by the headless host. It does not change guest ABI, firmware, VM, frame/input semantics or the desktop DevTools protocol.

The observation model is explained in Deterministic Observation Must Follow the Active Producer.

Process and transport

prometeu headless --stdio starts the distributed prometeu-headless tool from the same installation. One process owns one HeadlessHost. No display, native audio, network service or realtime pacing is required. A client must use its configured installation; missing binaries/capabilities are explicit failures.

Transport is UTF-8 JSON objects separated by LF (CRLF is accepted). stdout is protocol-only; diagnostics go to stderr. Fragmented reads must be accumulated; allocation is bounded by the command limit. An oversized line is rejected and drained through LF before reading the next request. EOF with an incomplete line reports invalid_request, then closes the session. EOF always requests shutdown.

All sizes exclude the LF delimiter and include the complete JSON envelope and base64 payload. Responses exceeding their bound become response_too_large, never truncated data. Clients must continuously consume stdout, including events. Backpressure may block output; the supervising client owns wall-clock deadlines and may terminate the process tree. There is no transport replay or durable queue.

Handshake and compatibility

The server first emits a hello object with sessionId, protocolVersion (major: 1, minor: 0), real runtimeVersion, capabilities and limits. Session identity is opaque and process-local, excluded from deterministic oracles.

Before work, the client sends initialize with protocolVersion and an array requiredCapabilities. An incompatible major returns incompatible_version; missing capabilities return unsupported_capability. The session remains uninitialized and cannot execute work. Compatible minor additions are permitted; the initialize result returns the lesser supported minor. Initialize is accepted once; repeated initialization returns already_initialized. Shutdown is permitted even before initialization. All other work requires successful initialization.

Envelopes

{"requestId":"a1","command":"advance","params":{"frames":60}}

requestId is a nonempty string of at most 128 UTF-8 bytes, selected by the client; concurrent requests must have distinct identities. command and params are required. Unknown fields and invalid parameter types are rejected. The request schema is distributed in devtools/headless-protocol/request.schema.json; response.schema.json defines hello, progress and every response/result shape. Valid and invalid request fixtures are shipped beside the schemas. Process tests validate actual server output against the response schema (including image results).

{"type":"response","sessionId":"opaque","requestId":"a1","result":{"requested":60,"completed":60,"stop":"completed"}}
{"type":"response","sessionId":"opaque","requestId":"a1","error":{"code":"busy","message":"...","details":{}}}

A response contains exactly one of result/error. Errors have stable code, human-readable message and structured details. Unparseable/unusable request identity is represented by null; valid identity is preserved on parameter errors. Malformed JSON, invalid schema and unknown commands must never disappear silently. Wire requestId is correlation, not deduplication: the client must not retry an advance blindly after a lost response. Studio task-level clientRequestId and operationId are a separate boundary, not part of this wire protocol.

Commands

Command Parameters Result/meaning
initialize protocolVersion, requiredCapabilities negotiated version and capabilities
boot path (nonempty directory-cartridge path) current state; existing boot preconditions apply
reset empty object reset state, clears input/fault/frame correlation
set_input complete snapshot fields listed below; omitted fields reset to defaults input replaced, not patched
clear_input empty object input restored to defaults
advance frames: unsigned integer, including zero requested, completed, stop, optional fault/error details
capture empty object PNG/base64 plus canonical frame metadata
get_state empty object pc, stackTop, logicalFrameIndex, tickIndex, appId, status
get_fault empty object fault object or null
cancel targetRequestId acknowledgement that cancellation was requested for that active advance
shutdown empty object acknowledgement after the active operation stops and host is dropped

Input snapshot fields are up, down, left, right, a, b, x, y, l, r, start, select, touch (booleans), and touchX, touchY (signed i32). Omitted booleans are false and omitted coordinates are zero. The ordinary runtime begin-frame sampling derives press/release/hold edges. No new input semantics exist.

State statuses are running, paused, terminated, faulted; running does not mean background execution. Stack values preserve their type through tagged kind/value objects; i64 values are decimal strings and float values carry an exact round-trippable string (including non-finite values). Faults expose kind, pc, summary and structural trap code/opcode/message/source span or init-error code. No client must parse a summary to distinguish trap, panic or initialization failure.

Resource traps include a nullable trap.resource object with resource, reason, requested and limit; resource and reason are enumerated machine values. initError is discriminated by code: registry_load_failed includes load, runtime_resource_limit includes resource, entrypoint_arguments_invalid includes entry, and loader_patch_failed includes binding. Other initialization codes carry only their code and human message. load.code uses the stable LOAD_* tag and retains typed reason, section/offset, record/member, ID domain, referenced ID, function/PC and quota context, with null for unavailable fields. Binding context preserves canonical native identity, version, capabilities or declared/expected ABI counts as applicable. A load-relative PC remains nested inside its diagnostic; initialization failure does not invent a runtime PC. The published response schema rejects unknown fields and invalid contexts.

Ordering, cancellation and lifecycle

Only one host operation is admitted at a time. Conflicting work, including state inspection while the host is executing, returns busy; it is not implicitly queued. The command reader remains available for cancel/shutdown while an advance executes. Cancellation targets an active advance's requestId; no active matching advance returns not_cancelable. An acknowledgement is not a completed cancellation.

Advancement is repeated advance_frame(), checking cancellation between frames. The current frame keeps the existing deterministic host-tick watchdog. Zero frames is a no-op. Results preserve requested/completed counts and stop values: completed, faulted, terminated, canceled, host_error. Guest faults are outcomes, not malformed-request errors. Host errors include a stable code and known completed progress; they do not manufacture guest faults.

Each completed frame emits type: progress, requestId, sessionId, requested and completed counts before the terminal response. A client can retain known progress if the process dies. The final response is authoritative when delivered.

Shutdown/EOF requests cancellation, waits for the active work to reach its boundary, drops the host and exits; explicit shutdown receives its response after cleanup. Disconnect never starts/resumes execution. A failed process requires a new explicit session, not replay. Host session loss does not implicitly release Studio authority.

Capture

Capture returns mimeType: image/png, encoding: base64, data, width, height, stridePixels, pixelFormat: RGBA8888, logicalFrameIndex and frameId. The envelope carries sessionId; the Studio consumer adds build correlation. Frame identities/counters on this wire are unsigned JSON integers and must be decoded losslessly. logicalFrameIndex and frameId have no numeric equality rule.

PNG stores visible RGBA channels in row order, losslessly, without stride padding. stridePixels describes the original canonical buffer. Before a completed frame, including after reset, capture returns no_frame_available; it cannot reuse an old run. No desktop screenshot, hash-only substitute, temporary-image-file transport or continuous video is permitted.

Configurable limits and supervision

CLI option / handshake field Default
--max-frames / maxFrames 600
--max-command-bytes / maxCommandBytes 65536
--max-response-bytes / maxResponseBytes 33554432
--handshake-timeout-ms / handshakeTimeoutMs 5000
--call-timeout-ms / callTimeoutMs 60000
--shutdown-timeout-ms / shutdownTimeoutMs 5000

Limits must be positive; message bounds must be at least 4096 bytes to admit the handshake and bounded errors. Limits apply to serialized bytes, not characters. Clients must enforce the advertised handshake/call deadlines and 5-second default cancel/shutdown grace, then terminate only the process tree they own. Deadlines are host supervision, not simulated guest time. Runtime enforces frame/message bounds without clamping. Requests over limits fail explicitly. Clients configure startup timeouts before seeing the handshake, then verify the announced values.

Conformance

The runtime gate includes fragmented/invalid/oversized lines, negotiation failures, all commands, busy/cancel/shutdown races, EOF, real CLI distribution invocation, PNG pixel equality, independent logical/render identity, repeat/reset determinism, structured faults, progress on partial failure and retained desktop run/debug. Neither Studio UI nor an AI model is required. See tests/automation_process.rs in prometeu-cli and the in-process deterministic-control tests in the headless crate.

Program Registry integration

When exposing initialization failures, retain the structured load error code, typed reason and available context. Human-readable messages are not a parsing contract; a load error has no fabricated runtime PC. Failed loads must not publish executable sessions. Existing protocol request names and transport behavior are unchanged.

Heap reference inspection values use {"kind":"heap_ref","value":{"index":u32,"generation":u32}}. Both components are required to distinguish a live incarnation from a reused slot; the wire representation must not truncate handles to indices. Inspection does not grant cross-session transfer authority.